MODEL
563
EXTENDED
SENSOR FACE LEVEL TRANSMITTER
HEAD PRESSURE TYPE
Download the
Delta Controls Model 563 Detailed Datasheet
Note: You will need the Acrobat Reader to view the data sheet.
Features
- Two Wire Loop Powered
- Intrinsically Safe 4-20
mADC
- Suitable For Difficult
Liquids And Slurries, Such As Sewage, Slop Tanks, Pulping Liquors, and Lime
Slurry
- ANSI, JIS, DIN Flanged
Or 1-1/2" NPT Connection
- 12 Inches To 1250 Foot
(0.3 to 30 M) Ranges
- Zero & Span Pots
Allow For Field Recalibration
- Spark, Voltage Surge
Protection
- Unaffected By Product
Coating
- Optional 20-4 mADC Calibration
- Optional Corrector Allows
Accurate Measurement Even When The Tank Is Pressurized, Under A Vacuum, Or
Both Cyclically
- Maintenance Free Operation
Description
The Delta
Controls Model 563 Level Transmitter consists of a potted electronic
module and a flush diaphragm pressure sensor packaged in a one piece unit. The
sensor is equipped with an oil filled 316-L S.S. or Hastelloy"C"®
diaphragm which isolates the strain gage bridge from the process liquid or gas.
The back of the diaphragm is vented to atmosphere to compensate for barometric
pressure changes. A desiccant filter or isolation bladder prevents moisture
buildup in the vent tube.
The Delta Controls Model
563 mounts on the side of, and at the bottom of a tank or other containment
and measures the pressure exerted on the sensor face by the liquid head. The
pressure at the bottom of a vented tank containing fluid is linearly proportional
to the height and density of the fluid. The flush diaphragm 563 is intended
for measurement of dirty or high solids content products that might easily plug
the small openings and tubing connections of typical transmitters. The extended
diaphragm configuration is typically used to gain access to the inside of a
tank to avoid being plugged by deposits and sediment. The extended face allows
the sensor to be located inside the vessel to insure that solids either fall
off or do not become rigid enough to cause measurement errors.
Specifications
- Technology:
Silicon strain gage
- Supply Power:
13 to 35 VDC 2 wire loop powered
- Output:
4-20 mADC isolated, Intrinsically Safe
- Loop Impedance:
550 ohms at 24 VDC. 1100 ohms at 35 VDC
- Adjustments:
Span from 30% to 100% of sensor range. Zero to 30% suppression is basic; to
80% optional; non-interative
- Over Pressure:
2X Range, 35 PSI (2.5 Bar) minimum without damage, 3X Range 1000 PSI (70 bar)
minimum without rupture
- Temperature
Range:
- -20 to +220°F (-30
to +105°C) Process
- -20 to +185°F (-30
to +85°C) Electronics
- 30 to +130°F (-1
to +55°C) Compensated (Higher Available)
- Accuracy:
± 0.25% F.S. or better
- Thermal Error:
± 0.02% FS/ °F maximum
Optional
Features
- Dampening:
Selectable 0.1 to 22 seconds
- Indicator:
Large direct reading LCD display
- DC Power Supply*:
Integral VAC to 24 VDC
- Alarm Module*:
Integral 5 amp, SPDT
- Liquid Temperature
Loop: Any 50°F to 250°F (30 to 140°C) Span between -50°F and +250°F
(or metric equivalent)
- TPC Corrector:
Used to correct for the gas space pressure when the tank is pressurized
Third Party
Listings
- CSA (Canada)
- NRTL/C (USA)
- Intrinsically Safe
- Explosion Proof
- Environment Proof
- ISO 9001 Quality System
Go to Delta
Controls Home Page
Go to Delta
Controls Pressure Transmitter Page